Alarm codeRRA...
This code indicates a remote alarm has been received in the service word. The manual's first action is: “An alarm interrupt status ISR2.RA can be generated when the alarm condition is detected.”
- Model
- Siemens FALC54
- Display shows
- Receive Remote Alarm (RRA...)
- Type
- Alarm code
- Source
- Manual p. 121
What RRA... means
Receive Remote Alarm p. 121
Common causes
- Set if bit 3 of the received service word is set. p. 121
- FRS0.RRA is cleared when no alarm is detected. p. 121
- The bit RSW.RRA has the same function. p. 121
- Both status and interrupt‑status bits are set during alarm simulation. p. 121
- The flag is set after detecting a remote alarm (yellow alarm). Conditions for setting and resetting are defined by bit RC1.RRAM. p. 121
- A rising edge on this bit generates interrupt status ISR2.RA. p. 121
- A falling edge on this bit generates interrupt status ISR2.RAR. p. 121
- The bit is set during alarm simulation and cleared if FRS2.ESC = 0, 3, 4, or 7 and no alarm condition exists. p. 121
What to do
- An alarm interrupt status ISR2.RA can be generated when the alarm condition is detected. p. 121
- At the same time a remote‑alarm recovery interrupt status ISR2.RAR will be generated. p. 121
If RRA... is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about RRA...; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.