Siemens FALC54 Error MFAR...: Multiframe Alignment Recovery

Siemens FALC54 · taken from the manufacturer’s manual, pages cited

Alarm codeMFAR...

This code indicates the framer has found two CRC-multiframes at intervals without a framing error. The manual lists no action for this code.

Model
Siemens FALC54
Display shows
Multiframe Alignment Recovery (MFAR...)
Type
Alarm code
Source
Manual p. 141

What MFAR... means

Multiframe Alignment Recovery p. 141

Common causes

  • Set when the framer has found two CRC‑multiframes at intervals of n × 2 ms (n = 1, 2, 3, …) without a framing error, and bit FRS0.LMFA is reset at the same time. p. 141
  • Also set after alarm simulation finishes while the receiver remains synchronized; active only if CRC‑multiframe format is selected. p. 141

If MFAR... is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about MFAR...; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.