Siemens FALC54 Error AIS...: Alarm Indication Signal

Siemens FALC54 · taken from the manufacturer’s manual, pages cited

Alarm codeAIS...

This code indicates an alarm indication signal has been detected. The manual's first action is: “The bit is reset when no alarm condition is detected (ETSI).”

Model
Siemens FALC54
Display shows
Alarm Indication Signal (AIS...)
Type
Alarm code
Source
Manual p. 120

What AIS... means

Alarm Indication Signal p. 120

Common causes

  • FMR0.ALM = 0: This bit is set when two or fewer zeros are detected in the received bit stream within a 250 µs interval while the FALC54 is in the asynchronous state (FRS0.LFA = 1). p. 120
  • FMR0.ALM = 1: This bit is set when the incoming signal has two or fewer zeros in each of two consecutive double‑frame periods (512 bits). p. 120
  • The bit is set when an alarm indication signal is detected and bit FRS0.AIS is set; it will also be set during alarm simulation. p. 120
  • If IPC.SCI is high, this interrupt‑status bit will be set with every change of state of FRS0.AIS. p. 120
  • The bit is set when the conditions defined by bit FMR4.AIS3 are detected. p. 120
  • A rising edge on this bit generates interrupt status ISR2.AIS. p. 120
  • The bit remains set during alarm simulation and is cleared if FRS2.ESC = 0, 3, 4, or 7 and no alarm condition exists. p. 120
  • The bit is set when an alarm indication signal is detected and bit FRS0.AIS is set. p. 120

What to do

  1. The bit is reset when no alarm condition is detected (ETSI). p. 120
  2. The bit is cleared when each of two consecutive double‑frame periods contains three or more zeros, or when the frame‑alignment signal FAS has been found (ITU‑T: G.775). p. 120
  3. The flag stays active for at least one multiframe. p. 120
  4. It is reset at the start of the next multiframe if no alarm condition is detected. p. 120
  5. If IPC.SCI is high, this interrupt‑status bit is activated with every change of state of FRS0.AIS and will be set during alarm simulation. p. 120

If AIS... is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about AIS...; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.