This code indicates loss of frame alignment has been detected. The manual's first action is: “A rising edge on this bit generates interrupt status ISR2.LFA. The loss‑of‑sync conditions are defined by bits RC1.SWD and RC1.ASY4. After loss of synchronization, the frame aligner will automatically resynchronize.”
- Model
- Siemens FALC54
- Display shows
- Loss of Frame Alignment (LFA...)
- Type
- Alarm code
- Source
- Manual p. 120
What LFA... means
Loss of Frame Alignment p. 120
Common causes
- The bit is set after detecting three or four consecutive incorrect FAS words or three or four consecutive incorrect service words (this detection can be disabled). p. 120
- The flag is set if pulse‑frame synchronization has been lost. p. 120
- The flag is cleared when synchronization is regained. p. 120
What to do
- A rising edge on this bit generates interrupt status ISR2.LFA. The loss‑of‑sync conditions are defined by bits RC1.SWD and RC1.ASY4. After loss of synchronization, the frame aligner will automatically resynchronize. p. 120
- The conditions are specified via bit FMR4.SSC1/0. Setting this bit causes interrupt status ISR2.LFA. p. 120
- Additionally, interrupt status ISR2.FAR is set when this bit is cleared. p. 120
If LFA... is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about LFA...; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.