Siemens FALC54 Error NMF...: No Multiframe Alignment Found

Siemens FALC54 · taken from the manufacturer’s manual, pages cited

Alarm codeNMF...

This code indicates the multiframe pattern could not be detected within the specified interval. The manual's first action is: “The receiver is automatically switched to double‑frame format. This bit is reset if the basic framing is lost.”

Model
Siemens FALC54
Display shows
No Multiframe Alignment Found (NMF...)
Type
Alarm code
Source
Manual p. 122

What NMF... means

No Multiframe Alignment Found p. 122

Common causes

  • Valid only when CRC‑4 interworking is selected (FMR2.RFS1/0 = 11). Set if the multiframe pattern cannot be detected within a 400 ms interval after the framer reaches the double‑frame synchronous state. p. 122

What to do

  1. The receiver is automatically switched to double‑frame format. This bit is reset if the basic framing is lost. p. 122

If NMF... is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about NMF...; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.