Siemens CU240B/E-2 Error A30042: Power unit: Fan operating time reached or exceeded

Control unit · taken from the manufacturer’s manual, pages cited

Fault codeA30042

The fan in the power unit has operated for more than 500 hours, exceeding its maximum allowed operating time. The manual's first action is: “This message indicates the following: Fault value (0949, decimal interpretation): 0: The maximum fan operating time is 500 hours. 1: The maximum fan operating time has been exceeded.”

Model
Siemens CU240B/E-2
Display shows
Power unit: Fan operating time reached or exceeded (A30042)
Type
Fault code
Source
Manual p. 718

What A30042 means

Power unit: Fan operating time reached or exceeded p. 718

Common causes

  • The maximum operating time of the fan in the power unit is set in p0252. p. 718

What to do

  1. This message indicates the following: Fault value (0949, decimal interpretation): 0: The maximum fan operating time is 500 hours. 1: The maximum fan operating time has been exceeded. p. 718
  2. Replace the fan in the power unit and reset the operating hours counter to 0 (p0251 = 0). p. 718

If A30042 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about A30042; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.