Alarm codeAL. 08
AL.08 indicates a large position control command due to improper acceleration/deceleration, torque restriction, or gain setup. The manual's first action is: “Power OFF→ON”
- Model
- Shihlin Electric SDA Series
- Display shows
- Over-large position control command (AL. 08)
- Type
- Alarm code
- Source
- Manual p. 198
What AL. 08 means
Over-large position control command p. 229
Common causes
- Incorrect setup of the acceleration / deceleration time parameter p. 229
- Inproper torque restriction setup p. 229
- Too small gain value setup p. 229
- Too big external load p. 229
- Position encoder wiring error p. 229
- Loosen position encoder p. 229
- Position encoder damaged p. 229
- Poor position encoder wiring p. 229
What to do
- Power OFF→ON p. 229
- Press SET at the current alarm screen p. 229
- Alarm reset (RES) signal p. 229
- Check if the acceleration / deceleration time constant is too small. p. 229
- Check if the torque restriction parameter (PA05) is too small. p. 229
- Make sure if the position control gain value (PB07) is too small. p. 229
- Check external load. p. 229
- Make sure that he wiring follows the recommendation from the manual. Making correct wiring. p. 229
- Check if the position of the encoder connector. Re-installation p. 229
- Abnormal motor Motor replacement p. 229
- Check if the wiring has been loosen. Reconnect the wiring. p. 229
If AL. 08 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Shihlin Electric service.
This page summarises what the manufacturer’s manual says about AL. 08; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shihlin Electric. Found a mistake? Report an error.