Error codeND20
[Total Input Energy] means accumulated input energy value exceeds 999.999 kWh. The manual's first action is: “Use logical input function 51 or parameter F74B to clear the accumulated input energy value.”
- Model
- Schneider Electric ATV212
- Display shows
- [Total Input Energy] (ND20)
- Type
- Error code
- Source
- Manual p. 154
What ND20 means
[Total Input Energy] p. 154
Common causes
- Accumulated input energy value exceeds 999.999 kWh. p. 154
What to do
- Use logical input function 51 or parameter F74B to clear the accumulated input energy value. p. 154
Before you service the product, read the safety instructions in the manual p. 5.
If ND20 is still not resolved
- 与当地的 Schneider Electric 代表联系 p. 7 “如果直流总线电容未完全放电,请与当地的 Schneider Electric 代表联系”
This page summarises what the manufacturer’s manual says about ND20; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.