An EEPROM error has occurred. The manual's first action is: “The unit must be returned to the factory or authorized service center for repair.”
The supply voltage at the S4000TH has dropped below +18.5 VDC. The manual's first action is: “Ensure that the supply voltage is at least +20 VDC at the S4000TH.”
A short-circuited sensor circuit lead has been detected. The manual's first action is: “Check the integrity of all sensor connections and ensure that the cable from the S4000TH to the remote sensor is not damaged. If …
Sensor Heater Open Error or Sensor Amplifier Error indicates a fault with the remote sensor's wiring or calibration. The manual's first action is: “Check the integrity of all sensor connections, and ensure that the ca…
Flash Checksum Error indicates a data integrity issue in the unit's internal system. The manual's first action is: “The unit must be returned to the factory or authorized service center for repair.”
The unit failed to complete calibration because no gas was applied within twelve minutes or gas was left on longer than twelve minutes. The manual's first action is: “Remove gas, if present. Apply magnet to GM logo on…
All 9 error codes of the General Monitors S4000TH General Monitors S4000TH with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
The CPU has encountered an error. The manual's first action is: “Reset the TMS7. If the problem persists contact your supplier.”
The TMS7 is fitted with an incompatible main control module. The manual's first action is: “1. Fit a suitable main control module.”
The TMS7 has detected an incorrect motor FLC setting for a 3 Wire connection. The manual's first action is: “1. Reduce the motor FLC setting and then reset the TMS7. Note that this FLC cannot be reset until the FLC se…
The TMS7 has failed to read or write to the internal EEPROM. The manual's first action is: “Reset the TMS7. If the problem persists contact your supplier.”
RS485 communication fault indicates inactive link for longer than set timeout. The manual's first action is: “1. Restore the RS485 link.”
The TMS7 cannot detect a valid motor circuit. The manual's first action is: “1. Ensure the motor is connected to the TMS7 in a valid configuration. Refer to Section 5 Power Circuits for further detail.”
The TMS7 heatsink temperature sensor has indicated an excess heatsink temperature. The manual's first action is: “1. Verify that the TMS7 has sufficient ventilation. 2. Verify that cooling air is able to freely circul…
The TMS7 has measured a run current lower than the limit set in Function 8. Undercurrent Protection. The manual's first action is: “1. Identify and correct the cause of the undercurrent event.”