Wrong I/O board version without specified cause. The manual lists no action for this code.
Sercos board or I/O board missing without specified cause. The manual lists no action for this code.
Error identifying the VeCon board without specified cause. The manual lists no action for this code.
Error identifying the serial line board without specified cause. The manual lists no action for this code.
Excessive rotor sensor signal drift caused by degraded signal quality, faulty wiring, encoder, X4 card, or ground connection. The manual's first action is: “Check the state of the cable, of the Encoder or of the X4 ca…
Direct feedback signals A and/or B too weak due to defective cabling, feedback device, or feedback board (X4/X3), or low parameter values RP1-RP4. The manual's first action is: “Check the cable, the feedback device, t…
Motor feedback signals A and/or B too weak without specified cause. The manual lists no action for this code.
Direct feedback signal saturation due to defective cabling, feedback device, or feedback board (X4/X3), or excessive parameter values RP1-RP4. The manual's first action is: “Check the cable, the feedback device, the c…
Saturation of motor feedback signals A and/or B without specified cause. The manual lists no action for this code.
Motor feedback A signal saturated due to defective rotor sensor cabling, encoder or X4 card, or excessive offset/gain settings. The manual's first action is: “Check the cable of the Encoder and that of the X4 card or …
The motor feedback B signal is saturated due to defective cabling or incorrect parameter settings. The manual's first action is: “Check the cable of the Encoder and that of the X4 card or increase the value of these p…
A communication error with the rotor encoder has occurred on software versions prior to 03.01, displayed as errors 8xx. The manual's first action is: “Check the sensor cable and if it is the right one, check the senso…
There is a communication error with the rotor encoder, indicating a potential hardware or connection issue. The manual lists no action for this code.
The connected motor does not match the one stored in Flash memory settings. The manual's first action is: “Save the parameters in Flash memory to work with the connected motor.”
An incorrect parameter is configured in the SERCOS stage two protocol. The manual's first action is: “Correct the parameter.”