The default motor values table has not been saved, causing a configuration error. The manual's first action is: “This table must be saved.”
A parameter has been set to an invalid value or conflicts with other settings. The manual's first action is: “Correct the parameter. The DV16 variable, indicated the code of the wrong parameter.”
There is an inconsistency in the system parameters. The manual lists no action for this code.
A phase downshift error has occurred, indicating a problem with the motor’s phase shifting mechanism. The manual lists no action for this code.
A phase upshift error has occurred, suggesting an issue with the motor’s phase shifting mechanism. The manual lists no action for this code.
An invalid phase error has been detected, indicating a problem with the motor's phase configuration. The manual lists no action for this code.
A MDT fault has occurred, with no specific cause listed. The manual lists no action for this code.
A MST fault has occurred, with no specific cause listed. The manual lists no action for this code.
The drive or motor protection has triggered due to excessive duty cycle. The manual lists no action for this code.
The motor is experiencing overload conditions. The manual lists no action for this code.
The motor speed has surpassed the SP10 value by more than 12% due to cable or control issues. The manual's first action is: “Decrease the speed overshoot of the response.”
The axis lag (following error) has exceeded the maximum allowed value set in PP159. The manual's first action is: “Check the setting of all these factors involved in "following error". Check the value given to PP159.”
The path demands an acceleration higher than what is permitted by the system settings. The manual's first action is: “Decrease the path demands in terms of required acceleration.”
The path requires a feedforward velocity that exceeds the system's capacity. The manual's first action is: “Decrease the path demands in terms of required feedrate.”
The command module has received a value exceeding the limit set by parameter PP103. The manual's first action is: “Check the value of this parameter together with its equivalent parameter at the CNC. Check that both t…