Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Software undervoltage happens when there’s a three-phase A.C. device instant outage, input power wires are loose, or rectifier bridge and buffer resistance are abnormal. The manual's first action is: “1.Check the wiri…
IGBT shortcircuit occurs from short circuits and ground connections on the output side, IGBT module damage, or technical support is needed. The manual's first action is: “1.Check the motor insulation or line-to-ground…
Hardware overcurrent happens due to short circuits and ground connections on the output side, IGBT module damage, or technical support is required. The manual's first action is: “1.Check the motor insulation or line-t…
Software overcurrent occurs when the current loop value (Pi) is too large, there’s a short circuit or ground connection on the output side, or the encoder wire is loose or disconnected. The manual's first action is: “…
Hardware overvoltage happens when the current loop value (Pi) is too large, there’s a short circuit or ground connection on the output side, or the encoder wire is loose or disconnected. The manual's first action is: …
Software overvoltage occurs when the voltage is too high, regenerated energy exceeds brake resistor consumption, or the brake resistor connection is loose or disconnected. The manual's first action is: “1.Check the A.…
All 56 error codes of the Ningbo Anson Hi Series servo drive with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Defective encoder because it is not working properly. The manual's first action is: “Contact Fagor Automation.”
Encoder not initialized without specified cause. The manual's first action is: “Contact Fagor Automation.”
Communication error with the Encoder without specified cause. The manual's first action is: “Contact Fagor Automation.”
Encoder undetected because GP2 is set to "0" (sinewave encoder) but a Resolver is actually installed. The manual's first action is: “The value of GP2 must be consistent with the feedback device installed. Contact Fago…
Error identifying the Encoder simulator board without specified cause. The manual lists no action for this code.
Error identifying the motor feedback board without specified cause. The manual lists no action for this code.
Error identifying the Power board without specified cause. The manual lists no action for this code.
Incorrect AD selection on the I/O board without specified cause. The manual lists no action for this code.