An error occurred during preprocessing of the position actual value from the encoder. The manual's first action is: “Check the encoder for the position actual value preprocessing.”
Following error exceeds tolerance limit, indicating significant deviation between setpoint and actual position. The manual's first action is: “Check the causes and resolve.”
Drive failed to reach positioning window within the set position monitoring time (p2545). The manual's first action is: “Check the causes and resolve.”
Drive exited the standstill monitoring window after the specified time expired. The manual's first action is: “Check the causes and resolve.”
Motor encoder moved beyond parameterized tolerance window during position tracking, causing loss of reference. The manual's first action is: “Reactivate the position tracking function (set p29243 = 1 -> 0 -> 1). Then …
Position tracking of load gear exceeded maximum absolute position actual value within 32-bit representation limits. The manual's first action is: “Reduce the multi-turn resolution (p29244).”
The reference point coordinate received for encoder adjustment lies outside the permissible range. The manual's first action is: “Set the reference point coordinate to a lower value than specified in the fault value. …
The ratio between multi-turn resolution and modulo range is not an integer, causing position adjustment to reset. The manual's first action is: “Make the ratio between the multi-turn resolution and the modulo range an…
The "master control by PLC" signal was missing or incorrect, preventing proper master control operation. The manual's first action is: “Check the input for "master control by PLC".”
The motor's limit rotation parameter (p29027) is inappropriate and causing a test signal error. The manual's first action is: “Modify the value of parameter p29027.”
The upper torque limit parameter is set lower than the lower torque limit, which is invalid. The manual's first action is: “The upper torque limit (p29050) must be ≥ lower torque limit (p29051)”
Control parameters have exceeded dynamic limits and are not usable because hardware lacks required features. The manual's first action is: “It is not necessary to change the parameters as they have already been correc…
Motor overtemperature due to overload, high ambient temperature, or sensor disconnection. The manual's first action is: “Reduce the motor load.”
Exceeded the maximum allowable errors in controller sign-of-life during cyclic operation on PROFIdrive. The manual's first action is: “• Physically check the bus (cables, connectors, terminating resistor, shielding, e…
The global clock synchronization signal failed, violating time grid specifications in DP communication. The manual's first action is: “• Check the physical bus configuration (cable, connector, terminating resistor, sh…