Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Tool radius compensation cannot be started or canceled using G2 or G3. The manual's first action is: “G2 or G3 can not be performed when starting or canceling the tool compensation. Modify the program.”
There is no cross point in tool nose radius compensation The manual's first action is: “Modify the program”
Communication error occurs when CNC baud rate does not match computer baud rate The manual's first action is: “Check whether the baud rate of CNC is consistent with that of the computer”
The file can not be found The manual's first action is: “Search the file again”
Tool offset number exceeds the range of 1-64. The manual's first action is: “Modify tool offset number, the range: 1-64”
The offset value specified by T code is too big. The manual's first action is: “Perform tool setting again, modify the offset value specified by T code.”
In circular interpolation, R and (K,I) are zero. The manual's first action is: “Specify radius of circle correctly when checking program.”
In circular interpolation, R and (K,I) are specified simultaneously. The manual's first action is: “Either R or (K,I) is used to specify radius of circular arc. Delete unneeded characters.”
The value specified in circular interpolation can not form a circular arc. The manual's first action is: “Modify program, radius, starting coordinate value or ending coordinate values of the circular arc.”
Radius of circular interpolation is too big. The manual's first action is: “Modify radius R. See programming manual.”
Circular interpolation radius R is defined as a negative value. The manual's first action is: “Circular radius R should not be a negative value, modify the program.”
The zero return block is at the edge of the block or factory settings cannot be covered. The manual's first action is: “zero return. Adjust position of zero return block, and perform zero return again.”
All 105 error codes of the GSK GSK980TB3 GSK GSK980TB3 with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
DSP address bus and memory cell error detected. The manual lists no action for this code.
DSP data bus error occurred, with six-digit hex code indicating which of the 24 data lines are faulty The manual lists no action for this code.