Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
An alarm occurs when more than two G codes in the same group are used in one block. The manual's first action is: “Modify the program. See programming manual for details.”
The sequence number for address transfer is out of range or not found. The manual's first action is: “Modify the program, and use the correct sequence number.”
An illegal variable number has been specified in the program. The manual's first action is: “Modify the program, and specify the correct variable number.”
In G65 block, undefined H code is specified. The manual's first action is: “Check program, and specify the correct H code.”
The program name already exists when copied and renamed. The manual's first action is: “Select a new program name, and perform again.”
The drive, spindle etc. are changing. The manual's first action is: “Restart the system again.”
The system detects abnormal absolute data and requires tool reset. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”
The system detects abnormal tool length compensation data. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”
CNC abnormality is detected, it needs to check parameter again. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”
Memory data, tool compensation and coordinate have been initialized. The manual's first action is: “Read initialized disk again. If they still exist after power on, please change the main board.”
The number of lines exceed the maximum value. The manual's first action is: “Delete redundant lines.”
In program editing, power is off. Please edit the program again. The manual's first action is: “Press reset key to cancel the alarm, and edit the program again.”
The parameter switch is turned ON. The manual's first action is: “Set parameter switch to the state of “OFF” (In MDI mode, press character “W” on the setting page), or press reset key.”
NC program and customer macro program exist simultaneously. The manual's first action is: “Modify the program. See programming manual for details.”
Macro code alarm does not exist. The manual's first action is: “Specify the correct macro code alarm number.”