All 23 error codes of the Faldic MHT259a (RYS-L type) AC Servo System with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
The system is monitoring fill levels but encountered an issue requiring water supply check. The manual's first action is: “Check water supply. Contact your HOBART Service Partner.”
The external water treatment unit has reached its capacity limit and needs replacement. The manual's first action is: “Replace part or full desalination cartridge.”
The wash tank had insufficient water at the start of a programme, triggering an automatic refill. The manual's first action is: “The machine refills automatically and starts the programme. If the error is permanently …
The boiler’s water level was being monitored for correct fill status. The manual's first action is: “Check water supply.”
The impeller sensor failed to monitor proper water fill levels during filling. The manual's first action is: “Check water supply.”
The tank is draining during a pump-out programme, and the pressure sensor detected an anomaly. The manual's first action is: “Clean the drain hose if necessary and pump out the machine again.”
The filling programme detected an issue with the tank pressure sensor. The manual's first action is: “Pump out machine.”
The wash tank’s water level regulation system failed to function properly. The manual's first action is: “Contact your HOBART Service Partner.”
The tank pressure sensor reading fell below its minimum acceptable value. The manual's first action is: “Contact your HOBART Service Partner.”
The tank pressure sensor reading exceeded its maximum safe value. The manual's first action is: “Contact your HOBART Service Partner.”
The boiler pressure sensor reading is below the minimum acceptable level. The manual's first action is: “Contact your HOBART Service Partner.”
The boiler pressure sensor reached its upper limit. The manual's first action is: “Contact your HOBART Service Partner.”
The tank sensor detected a temperature that was too low. The manual's first action is: “Contact your HOBART Service Partner.”
The tank sensor detected a temperature that exceeded its safe limit. The manual's first action is: “Contact your HOBART Service Partner.”