Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
T code is wrong. Illegal T code is edited in the program. The manual's first action is: “Corresponding parameter is not set. See parameter list of the manual.”
S code is wrong. Illegal S code is edited in the program. The manual's first action is: “Corresponding parameter is not set. See parameter list of the manual.”
M code is wrong. Illegal M code is edited in the program. The manual's first action is: “Corresponding parameter is not set. See parameter list of the manual.”
M41-M44 cannot be used when spindle is in gear control or automatic gearing is inactive. The manual's first action is: “Requirements for using M41-M44: frequency conversion and spindle automatic gearing is active. Cha…
The spindle enable signal is not being received. The manual's first action is: “Check SPEN input state of parameter NO.3, and check whether circuit of the external spindle enable signal is normal, or change parameter …
Incorrect password entered before modifying parameters or screw pitch compensation data. The manual's first action is: “It is necessary to input password before modifying parameter and screw pitch. See programming man…
Q and R in macro program are specified incorrectly. The manual's first action is: “Check the program. See the programming manual for details.”
P,U and X in the pause command can not be specified at the same time. The manual's first action is: “Delete unnecessary address characters.”
Pno and Qno values assigned by G70, G71, G72, or G73 exceed the range or are non-integral. The manual's first action is: “Check the program. See the programming manual for details.”
The sentence for calling subprogram or returning subprogram is in illegal block (G90-G94, G70~G76). The manual's first action is: “Check the program. See the programming manual for details.”
The system has exceeded its maximum storage limit of 500 programs. The manual's first action is: “Delete unnecessary program.”
Subprogram is called too many times. The manual's first action is: “Subprogram call times: 1-999. Modify the program.”
The program contains a non-integral or negative value for parameter P. The manual's first action is: “Check the program. See the programming manual for details.”
Group G00 and group G01 cannot both be active simultaneously in the program. The manual's first action is: “Modify the program, and delete redundant G code.”
The value of the address exceeds the range. The manual's first action is: “There are specified ranges for addresses. Modify the program. See programming manual for details.”