The X-axis hardware has traveled beyond its negative limit. The manual lists no action for this code.
The Y-axis negative stroke has exceeded its programmed limit. The manual's first action is: “Modify the range of Y-axis negative stroke of the CNC parameter or cancel alarm by manual negative feed.”
The Y-axis positive stroke has exceeded its programmed limit. The manual's first action is: “Modify the range of Y-axis positive stroke of the CNC parameter or cancel alarm by manual negative feed.”
The Z-axis negative stroke has exceeded its programmed limit. The manual's first action is: “Modify the range of Z-axis negative stroke of the CNC parameter or cancel alarm by manual negative feed.”
The X-axis has exceeded its positive stroke limit. The manual's first action is: “Modify the range of Z-axis positive stroke of the CNC parameter or cancel alarm by manual negative feed.”
The X-axis negative stroke has exceeded its limit. The manual's first action is: “Modify the range of X-axis negative stroke of the CNC parameter or cancel alarm by manual negative feed.”
The X-axis positive stroke has exceeded its limit. The manual's first action is: “Modify the range of X-axis positive stroke of the CNC parameter, or cancel alarm by manual negative feed.”
The system is requesting the U-disk to be removed during operation. The manual's first action is: “U-disk should not be plugged in during processing.”
The system detected continuous pressing of the cycle start key. The manual's first action is: “Adjust parameter P159 key pressing time.”
Axis number has been changed and data initialization was successful. The manual's first action is: “Press reset key to cancel the alarm when CNC alarms. After turning off the parameter switch, press reset key to conti…
The system did not receive a signal that the chuck is in position within the allowed time. The manual's first action is: “Check whether the wire of external alarm is correct. Adjust parameter P91 arrival time or modif…
M45~M49 commands are executed while corresponding in-position input signal is not received. The manual's first action is: “In-position input signal is necessary for executing M45-M49. Check whether the circuit is corr…
Tool change is not ready because tool number does not match current tool number. The manual's first action is: “Press reset key to cancel the alarm or adjust position of signal sending disk, or according to the state …
The system has not received the tool post’s reverse locking signal within the tool post reverse locking time. The manual's first action is: “According to TCP input state of parameter NO.1 Bit7, check whether the setti…
Alarm 185 occurs when tool changing time exceeds set limit and tool position signal is not received. The manual's first action is: “According to input state of NO.2 T01-T08, check whether the setting of NO.9 Bit1 is c…