Fault code34
This code indicates overflow operation limit fault. The manual's first action is: “Possible”
- Model
- Omron OMNUC G
- Display shows
- Overflow operation limit fault (34)
- Type
- Fault code
- Source
- Manual p. 343
What 34 means
Overflow operation limit fault p. 402
Common causes
- For position command input, the motor exceeds the action range set by the overtravel limit setting (Pn26). p. 402
- Operation exceeds the overtravel limit setting (Pn26). p. 402
What to do
- Possible p. 402
- • Adjust gain • Increase the Pn26 setting value • Set Pn26 to 0 to disable the function. p. 402
Before you service the product, read the safety instructions in the manual p. 273.
If 34 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.