Omron OMNUC G Error 34: Overflow operation limit fault

Omron OMNUC G · taken from the manufacturer’s manual, pages cited

Fault code34

This code indicates overflow operation limit fault. The manual's first action is: “Possible”

Model
Omron OMNUC G
Display shows
Overflow operation limit fault (34)
Type
Fault code
Source
Manual p. 343

What 34 means

Overflow operation limit fault p. 402

Common causes

  • For position command input, the motor exceeds the action range set by the overtravel limit setting (Pn26). p. 402
  • Operation exceeds the overtravel limit setting (Pn26). p. 402

What to do

  1. Possible p. 402
  2. • Adjust gain • Increase the Pn26 setting value • Set Pn26 to 0 to disable the function. p. 402

Before you service the product, read the safety instructions in the manual p. 273.

If 34 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.