Omron OMNUC G Error 27: Electronic gear setting fault

Omron OMNUC G · taken from the manufacturer’s manual, pages cited

Fault code27

This code indicates electronic gear setting fault. The manual's first action is: “Possible”

Model
Omron OMNUC G
Display shows
Electronic gear setting fault (27)
Type
Fault code
Source
Manual p. 343

What 27 means

Electronic gear setting fault p. 402

Common causes

  • Electronic gear ratio setting (Pn48~4B) is inappropriate. p. 402
  • Improper setting of electronic gear ratio numerator (Pn48, Pn49). p. 402

What to do

  1. Possible p. 402
  2. Set Pn48 and Pn49 so that command pulse frequency is below 500 kpps. p. 402

Before you service the product, read the safety instructions in the manual p. 273.

If 27 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.

This page summarises what the manufacturer’s manual says about 27; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.