Error code26
This code indicates overspeed. The manual's first action is: “Possible”
- Model
- Omron OMNUC G
- Display shows
- Overspeed (26)
- Type
- Error code
- Source
- Manual p. 343
What 26 means
Overspeed p. 402
Common causes
- Motor rotation speed exceeds the maximum speed. p. 402
- Speed command input too large. p. 402
- Improper setting of electronic gear ratio numerator (Pn48, Pn49). p. 402
- Overshoot operation causing speed to exceed the maximum. p. 402
- Encoder wiring misconnection. p. 402
- Exceeds the overspeed check level setting (Pn70). p. 402
What to do
- Possible p. 402
- Reduce command pulse frequency to below 500 kpps. p. 402
- Set Pn48 and Pn49 so that command pulse frequency is below 500 kpps. p. 402
- Adjust gain to lower the maximum command speed. p. 402
- Please ensure correct wiring. p. 402
- When using the torque limit switching function, correctly set the motor's operating speed range to Pn70. p. 402
Before you service the product, read the safety instructions in the manual p. 273.
If 26 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.