Error code24
This code indicates deviation counter overflow. The manual's first action is: “Possible”
- Model
- Omron OMNUC G
- Display shows
- Deviation counter overflow (24)
- Type
- Error code
- Source
- Manual p. 343
What 24 means
Deviation counter overflow p. 402
Common causes
- Accumulated pulses of the deviation counter exceed the overflow level (Pn70) setting. p. 402
- Motor power line or encoder wiring misconnection. p. 402
- Mechanical lock. p. 402
- Control board abnormal. p. 402
- Insufficient gain adjustment. p. 402
- Acceleration/deceleration too aggressive. p. 402
- Excessive load. p. 402
- Exceeds the deviation counter overflow level (Pn70) setting. p. 402
What to do
- Possible p. 402
- Correct wiring. p. 402
- If the mechanical shaft is locked, correct it and release the electromagnetic brake. p. 402
- Replace the drive. p. 402
- Adjust gain. p. 402
- Extend acceleration/deceleration time. p. 402
- Reduce load and reselect motor. p. 402
- Increase the Pn70 setting, slow down rotation speed, reduce load, and extend acceleration/deceleration time. p. 402
Before you service the product, read the safety instructions in the manual p. 273.
If 24 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.
This page summarises what the manufacturer’s manual says about 24; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.
