Omron OMNUC G Error 24: Deviation counter overflow

Omron OMNUC G · taken from the manufacturer’s manual, pages cited

Error code24

This code indicates deviation counter overflow. The manual's first action is: “Possible”

Model
Omron OMNUC G
Display shows
Deviation counter overflow (24)
Type
Error code
Source
Manual p. 343

What 24 means

Deviation counter overflow p. 402

Common causes

  • Accumulated pulses of the deviation counter exceed the overflow level (Pn70) setting. p. 402
  • Motor power line or encoder wiring misconnection. p. 402
  • Mechanical lock. p. 402
  • Control board abnormal. p. 402
  • Insufficient gain adjustment. p. 402
  • Acceleration/deceleration too aggressive. p. 402
  • Excessive load. p. 402
  • Exceeds the deviation counter overflow level (Pn70) setting. p. 402

What to do

  1. Possible p. 402
  2. Correct wiring. p. 402
  3. If the mechanical shaft is locked, correct it and release the electromagnetic brake. p. 402
  4. Replace the drive. p. 402
  5. Adjust gain. p. 402
  6. Extend acceleration/deceleration time. p. 402
  7. Reduce load and reselect motor. p. 402
  8. Increase the Pn70 setting, slow down rotation speed, reduce load, and extend acceleration/deceleration time. p. 402

Before you service the product, read the safety instructions in the manual p. 273.

If 24 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.