Omron OMNUC G Error 23: Encoder communication fault

Omron OMNUC G · taken from the manufacturer’s manual, pages cited

Fault code23

This code indicates encoder communication fault. The manual's first action is: “No”

Model
Omron OMNUC G
Display shows
Encoder communication fault (23)
Type
Fault code
Source
Manual p. 343

What 23 means

Encoder communication fault p. 402

Common causes

  • No communication between encoder and drive. p. 402
  • Encoder signal wiring misconnection. p. 402
  • Encoder wiring is interfered with, causing false operation. p. 402
  • Encoder power supply voltage drops (especially with long cable length). p. 402

What to do

  1. No p. 402
  2. Correct wiring. p. 402
  3. Implement anti‑interference measures on encoder wiring. p. 402
  4. Ensure encoder power voltage (DC5V ±5%). p. 402

Before you service the product, read the safety instructions in the manual p. 273.

If 23 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.