This code indicates analog input too large 1. The manual's first action is: “Possible”
- Model
- Omron OMNUC G
- Display shows
- Analog input too large 1 (39)
- Type
- Error code
- Source
- Manual p. 343
What 39 means
Analog input too large 1 p. 402
Common causes
- The current flowing in the analog command input (pin 14) exceeds the overflow level setting (Pn71) for speed/torque command input. p. 402
- Voltage applied to pin 14 is too high. p. 402
What to do
Before you service the product, read the safety instructions in the manual p. 273.
If 39 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.