Fault code38

This code indicates drive inhibit input fault. The manual's first action is: “Possible”

Model
Omron OMNUC G
Display shows
Drive inhibit input fault (38)
Type
Fault code
Source
Manual p. 343

What 38 means

Drive inhibit input fault p. 402

Common causes

  • Both forward drive inhibit and reverse drive inhibit are OFF. p. 402
  • Forward side drive inhibit (POT) input and reverse side drive inhibit (NOT) input are both disabled. p. 402

What to do

  1. Possible p. 402
  2. • Ensure proper wiring • Replace limit sensor • Verify that the control power supply is correct • Confirm that the drive inhibit input selection (Pn04) is set correctly. p. 402

Before you service the product, read the safety instructions in the manual p. 273.

If 38 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.