Omron CS1W-LCB01 and CS1W-LCB05 Error 3: Variable value error

Omron CS1W-LCB01 and CS1W-LCB05 Loop Control Board · taken from the manufacturer’s manual, pages cited

Error code3

A constant between A1 and A8 or an intermediate buffer between B1 and B4 that is used in the conditional statement for Arithmetic Operation (Block Model 126) is not defined. The manual's first action is: “Execution of the Arithmetic Operation block will be stopped. Set definitions for all constants A1 to A8 and an intermediate buffers B1 to B4 that are used.”

Model
Omron CS1W-LCB01 and CS1W-LCB05
Display shows
Variable value error (3)
Type
Error code
Source
Manual p. 185

What 3 means

Variable value error p. 185

Common causes

  • A constant between A1 and A8 or an intermediate buffer between B1 and B4 that is used in the conditional statement for Arithmetic Operation (Block Model 126) is not defined. p. 185

What to do

  1. Execution of the Arithmetic Operation block will be stopped. Set definitions for all constants A1 to A8 and an intermediate buffers B1 to B4 that are used. p. 185

Before you service the product, read the safety instructions in the manual p. 11.

If 3 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.