Error code51
Overload 2 occurs when servo current exceeds 95% for one second or spindle load exceeds continuous rating for 30 minutes during operation. The manual's first action is: “NR”
- Model
- Mitsubishi Electric MDS-C1 Series
- Display shows
- Overload 2 (51)
- Type
- Error code
- Source
- Manual p. 311
What 51 means
Overload 2 p. 311
Common causes
- With the servo, a current command exceeding 95% of the unit's maximum current continued for one second or more. With the spindle, a load exceeding the continuous rating continued for 30 minutes or more. p. 311
- The alarm occurred after ready ON before operation starts. p. 311
- The alarm occurred after normal operation. p. 311
What to do
Before you service the product, read the safety instructions in the manual p. 4.
If 51 is still not resolved
- contact service / dealer p. 5 “Wiring, maintenance and inspection work must be done by a qualified technician.”
This page summarises what the manufacturer’s manual says about 51; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.