Accumulated operation overload ratio reached the warning level (0x2010). The manual's first action is: “Check for equipment clash or arrest. Check load status, brake action, drive output miss wiring, encoder miss wiring. Check motor ID, drive ID, encoder setting”
- Model
- LS Mecapion L7P INDEXER Series
- Display shows
- Operation overload (W10)
- Type
- Warning code
- Source
- Manual p. 192
What W10 means
Operation overload p. 275
Common causes
- Accumulated operation overload ratio reached the warning level (0x2010). p. 275
What to do
- Check for equipment clash or arrest. Check load status, brake action, drive output miss wiring, encoder miss wiring. Check motor ID, drive ID, encoder setting p. 275
If W10 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact LS Mecapion service.
This page summarises what the manufacturer’s manual says about W10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with LS Mecapion. Found a mistake? Report an error.