LS Mecapion L7P INDEXER Series Error AL11: Regeneration overload IPM temperature

AC servo · taken from the manufacturer’s manual, pages cited

Error codeAL11

Surroundings temperature, Continuous Overload alaram, Motor cable open The manual's first action is: “Check whether surrounding temperature is over 50 [C]”

Model
LS Mecapion L7P INDEXER Series
Display shows
Regeneration overload IPM temperature (AL11)
Type
Error code
Source
Manual p. 269

What AL11 means

Regeneration overload IPM temperature p. 269

Common causes

  • surroundings temperature p. 269
  • Continuous Overload alaram p. 269
  • Motor cable open p. 269
  • Drive setting direction p. 269

What to do

  1. Check whether surrounding temperature is over 50 [C] p. 269
  2. Accumulated operate overload percentage [0x2803] Checking the load percentage is under 100% p. 269
  3. Check accumulated regenerative overload[0x2606] p. 269
  4. Check drive setting status p. 269

If AL11 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact LS Mecapion service.

This page summarises what the manufacturer’s manual says about AL11; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with LS Mecapion. Found a mistake? Report an error.