GSK GS2000T Series Error Err-19: The DC bus voltage is excessive, but there is no braking.

AC servo drive unit · taken from the manufacturer’s manual, pages cited

Fault codeErr-19

DC bus voltage is excessive without braking due to braking circuit fault or open circuit on braking resistor or unconnected resistor. The manual's first action is: “Change the servo drive unit.”

Model
GSK GS2000T Series
Display shows
The DC bus voltage is excessive, but there is no braking. (Err-19)
Type
Fault code
Source
Manual p. 122

What Err-19 means

The DC bus voltage is excessive, but there is no braking. p. 122

Common causes

  • Braking circuit fault; p. 122
  • Open circuit occurs on braking resistor or the braking resistor is not connected. p. 122

What to do

  1. Change the servo drive unit. p. 122
  2. Check the connection of braking resistor. p. 122

If Err-19 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.

This page summarises what the manufacturer’s manual says about Err-19; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GSK. Found a mistake? Report an error.