Delta CP2000 Error ocn: Oc at normal SPD

Variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codeocn

Overcurrent during operation; during constant speed, output current exceeds three times the inverter's rated current. The manual's first action is: “Check whether the U‑V‑W wiring to the motor has poor insulation; increase deceleration time; replace with a higher‑output‑capacity AC motor drive.”

Model
Delta CP2000
Display shows
Oc at normal SPD (ocn)
Type
Error code
Source
Manual p. 333

What ocn means

Oc at normal SPD p. 333

Common causes

  • Overcurrent during operation; during constant speed, output current exceeds three times the inverter's rated current. p. 333

What to do

  1. Check whether the U‑V‑W wiring to the motor has poor insulation; increase deceleration time; replace with a higher‑output‑capacity AC motor drive. p. 333

Before you service the product, read the safety instructions in the manual p. 327.

If ocn is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about ocn; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.