AL123 indicates a Data type (size) error occurs when accessing CANopen PDO object when the data length in the message does not match the specified object. The manual's first action is: “Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).”
- Model
- Delta ASDA-A2
- Display shows
- AL123
- Type
- Fault code
- Source
- Manual p. 55
What AL123 means
Data type (size) error occurs when accessing CANopen PDO object. p. 55
Common causes
- The data length in the message does not match the specified object. p. 55
What to do
- Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset). p. 55
If AL123 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL123; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.