Delta ASDA-A2 Error AL122: Sub-index error occurs when accessing CANopen PDO object.

Delta ASDA-A2 · taken from the manufacturer’s manual, pages cited

Fault codeAL122

AL122 indicates a Sub-index error occurs when accessing CANopen PDO object when the specified Sub-index in the message does not exist. The manual's first action is: “Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).”

Model
Delta ASDA-A2
Display shows
Sub-index error occurs when accessing CANopen PDO object. (AL122)
Type
Fault code
Source
Manual p. 54

What AL122 means

Sub-index error occurs when accessing CANopen PDO object. p. 54

Common causes

  • The specified Sub-index in the message does not exist. p. 54

What to do

  1. Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset). p. 54

If AL122 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL122; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.