AL126 indicates a CANopen PDO object does not support PDO when the specified object in the message does not support PDO. The manual's first action is: “Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).”
- Model
- Delta ASDA-A2
- Display shows
- CANopen PDO object does not support PDO. (AL126)
- Type
- Fault code
- Source
- Manual p. 55
What AL126 means
CANopen PDO object does not support PDO. p. 55
Common causes
- The specified object in the message does not support PDO. p. 55
What to do
- Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset). p. 55
If AL126 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL126; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.