Delta ASDA-A2 Error AL112: CANopen PDO receive buffer overrun

Delta ASDA-A2 · taken from the manufacturer’s manual, pages cited

Fault codeAL112

AL112 indicates a CANopen PDO receive buffer overrun when PDO Rx buffer overrun is detected (receive two or more PDO (same COBID) packets in 1ms). The manual's first action is: “Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).”

Model
Delta ASDA-A2
Display shows
CANopen PDO receive buffer overrun (AL112)
Type
Fault code
Source
Manual p. 54

What AL112 means

CANopen PDO receive buffer overrun p. 54

Common causes

  • PDO Rx buffer overrun is detected (receive two or more PDO (same COBID) packets in 1ms). p. 54

What to do

  1. Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset). p. 54

If AL112 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL112; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.