AL111 indicates a CANopen SDO receive buffer overrun when SDO Rx buffer overrun is detected (receive two or more SDO packets in 1ms). The manual's first action is: “Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).”
- Model
- Delta ASDA-A2
- Display shows
- CANopen SDO receive buffer overrun (AL111)
- Type
- Fault code
- Source
- Manual p. 54
What AL111 means
CANopen SDO receive buffer overrun p. 54
Common causes
- SDO Rx buffer overrun is detected (receive two or more SDO packets in 1ms). p. 54
What to do
- Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset). p. 54
If AL111 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL111; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.