Delta ASDA-A2 Error AL128: Error occurs when reading CANopen PDO object from EE-PROM.

Delta ASDA-A2 · taken from the manufacturer’s manual, pages cited

Fault codeAL128

AL128 indicates an error occurs when reading CANopen PDO object from EE-PROM when an error occurs when loading the default settings from EE-PROM at start-up. The manual's first action is: “Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).”

Model
Delta ASDA-A2
Display shows
Error occurs when reading CANopen PDO object from EE-PROM. (AL128)
Type
Fault code
Source
Manual p. 55

What AL128 means

Error occurs when reading CANopen PDO object from EE-PROM. p. 55

Common causes

  • An error occurs when loading the default settings from EE-PROM at start-up. All CANopen objects return to their default settings automatically. p. 55

What to do

  1. Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset). p. 55

If AL128 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL128; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.