TDK-Lambda PFH500F Manuals

ManualLib has 2 documents for the TDK-Lambda PFH500F (AC-DC Power): 1 datasheet, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Datasheet 1User Manual 1

Key facts

Model
PFH500F
Category
AC-DC Power
Industry
Electronics
Documents
2
Languages
EN
Last added
2026-11-24

Start here

TDK-Lambda PFH500F Series Evaluation Board Instruction Manual

TDK-Lambda PFH500F Series Evaluation Board Instruction Manual

User Manual 21 pages · 6.3 MB · EN

This instruction manual covers the TDK-Lambda PFH05W evaluation test board (PFH05W##-100-EVK-S1 and PFH05W##-1D0-EVK-S1) used to evaluate PFH500F AC-DC power modules. It opens with safety warnings and cautions, lists the reference documents, and gives ordering information for the kits, which accept 85-265 Vac 50/60 Hz input and are offered with 12 V, 28 V or 48 Vdc output modules in non-droop or droop mode versions.

The getting-started chapters describe the required test equipment, the input and output connections, and the primary and secondary test points, followed by the PMBus connection (J301), the remote on/off switch SW200, the auxiliary voltage and power-good LEDs, and how to set the PMBus address. The remaining chapters provide the electrical schematic drawing, bill of material and board files, including bottom layer and component placement figures.

Read online

TDK-Lambda PFH500F specifications

Nominal output power500 W
Maximum output power504 W
Input voltage range85–265 Vac; low-line derating may apply
Input frequency47–63 Hz
Nominal output voltages12, 28 and 48 Vdc
Typical efficiency90/92% at 115/230 Vac and 100% load for PFH500F-12 and PFH500F-28
Package size101.6 x 61.0 x 13.3 mm (4.00 x 2.40 x 0.53 in)
Weight225 g
Operating baseplate temperature-40 to 100 °C; see derating curves
CoolingConduction
Communications interfaceI²C / PMBus
Auxiliary output10–14 Vdc at up to 200 mA
Safety certifications and markingsIEC/UL/CSA/EN62368-1, 60950-1, CE and UKCA

Source: TDK-Lambda PFH500F Series 500W AC-DC Power Modules Data Sheet

All TDK-Lambda PFH500F documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What input voltage range do the PFH500F modules accept?

They accept 85–265 Vac; low-line derating may apply.

From: TDK-Lambda PFH500F Series 500W AC-DC Power Modules Data Sheet

Which nominal output voltages are available?

The series offers nominal 12, 28 and 48 V outputs.

From: TDK-Lambda PFH500F Series 500W AC-DC Power Modules Data Sheet

What test equipment is needed for the evaluation board?

An adjustable single-phase AC source of 85-265 Vac, 47-63 Hz, a DC multimeter with a 0-500 V range, a DC output load rated 60 Vdc or greater and 500 W or greater, and a fan for airflow across the module heatsink.

From: TDK-Lambda PFH500F Series Evaluation Board Instruction Manual

What is the factory default PMBus address?

The default address is 0x19 (Hex), with R318 not populated and R319 populated with 1.00K.

From: TDK-Lambda PFH500F Series Evaluation Board Instruction Manual