Key facts
- Brand
- TDK-Lambda
- Model
- PFH500F
- Category
- AC-DC Power
- Industry
- Electronics
- Documents
- 2
- Languages
- EN
- Last added
- 2026-11-24
Start here

TDK-Lambda PFH500F Series Evaluation Board Instruction Manual
This instruction manual covers the TDK-Lambda PFH05W evaluation test board (PFH05W##-100-EVK-S1 and PFH05W##-1D0-EVK-S1) used to evaluate PFH500F AC-DC power modules. It opens with safety warnings and cautions, lists the reference documents, and gives ordering information for the kits, which accept 85-265 Vac 50/60 Hz input and are offered with 12 V, 28 V or 48 Vdc output modules in non-droop or droop mode versions.
The getting-started chapters describe the required test equipment, the input and output connections, and the primary and secondary test points, followed by the PMBus connection (J301), the remote on/off switch SW200, the auxiliary voltage and power-good LEDs, and how to set the PMBus address. The remaining chapters provide the electrical schematic drawing, bill of material and board files, including bottom layer and component placement figures.
TDK-Lambda PFH500F specifications
| Nominal output power | 500 W |
|---|---|
| Maximum output power | 504 W |
| Input voltage range | 85–265 Vac; low-line derating may apply |
| Input frequency | 47–63 Hz |
| Nominal output voltages | 12, 28 and 48 Vdc |
| Typical efficiency | 90/92% at 115/230 Vac and 100% load for PFH500F-12 and PFH500F-28 |
| Package size | 101.6 x 61.0 x 13.3 mm (4.00 x 2.40 x 0.53 in) |
| Weight | 225 g |
| Operating baseplate temperature | -40 to 100 °C; see derating curves |
| Cooling | Conduction |
| Communications interface | I²C / PMBus |
| Auxiliary output | 10–14 Vdc at up to 200 mA |
| Safety certifications and markings | IEC/UL/CSA/EN62368-1, 60950-1, CE and UKCA |
Source: TDK-Lambda PFH500F Series 500W AC-DC Power Modules Data Sheet
All TDK-Lambda PFH500F documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What input voltage range do the PFH500F modules accept?
They accept 85–265 Vac; low-line derating may apply.
From: TDK-Lambda PFH500F Series 500W AC-DC Power Modules Data Sheet
Which nominal output voltages are available?
The series offers nominal 12, 28 and 48 V outputs.
From: TDK-Lambda PFH500F Series 500W AC-DC Power Modules Data Sheet
What test equipment is needed for the evaluation board?
An adjustable single-phase AC source of 85-265 Vac, 47-63 Hz, a DC multimeter with a 0-500 V range, a DC output load rated 60 Vdc or greater and 500 W or greater, and a fan for airflow across the module heatsink.
From: TDK-Lambda PFH500F Series Evaluation Board Instruction Manual
What is the factory default PMBus address?
The default address is 0x19 (Hex), with R318 not populated and R319 populated with 1.00K.