TDK-Lambda PFE500F Series Power Supply Unit Instruction Manual
This manual provides safety warnings and operational guidelines for the TDK-Lambda PFE500F series power supply units. It emphasizes precautions against electrical shock, fire hazards, and improper handling. Key safety notes include avoiding use in flammable environments, not modifying the unit, and ensuring proper installation with external fuses. The manual also covers terminal functions, input/output specifications, and environmental operating conditions.
The document includes detailed terminal explanations, connection diagrams, and specifications such as input voltage range (85–265VAC), output voltage adjustment, overcurrent and overvoltage protection, and recommended soldering conditions. It also addresses safety compliance, including SELV (Safety Extra-Low Voltage) requirements and insulation standards.
TDK-Lambda PFE500F specifications
| Input Voltage Range | 85 to 265VAC |
|---|---|
| Line Frequency Range | 47 to 63Hz |
| Output Voltage Adjustment Range | via TRIM terminal |
| Maximum Output Ripple and Noise | not specified in text |
| Maximum Line Regulation | not specified in text |
| Maximum Load Regulation | not specified in text |
| Over Current Protection (OCP) | not specified in text |
| Over Voltage Protection (OVP) | not specified in text |
| Over Temperature Protection (OTP) | not specified in text |
| Operating Temperature Range | not specified in text |
| Operating Humidity | not specified in text |
| Storage Temperature | not specified in text |
| Storage Humidity | not specified in text |
| Cooling Method | not specified in text |
| Withstand Voltage | not specified in text |
| Insulation Resistance | not specified in text |
| Recommended External Fuse | F15AH, 250V |
| Input Filter | For VCCI-class A |
| Recommended Voltage Rating for Capacitors | 250VAC |
| Inductors L1, L2 | 6mH |
Source: TDK-Lambda PFE500F Series Power Supply Unit Instruction Manual
All TDK-Lambda PFE500F documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the input voltage range for the PFE500F series?
The input voltage range is 85 to 265VAC.
From: TDK-Lambda PFE500F Series Power Supply Unit Instruction Manual
What type of fuse is recommended for the PFE500F series?
A fast-blown external fuse rated F15AH, 250V is recommended.
From: TDK-Lambda PFE500F Series Power Supply Unit Instruction Manual
Who is permitted to perform repairs on this power supply?
Only TDK-Lambda UK LTD and their authorised agents are permitted to carry out repairs.
What is the maximum hazardous energy output of this product?
The main output of this product is capable of providing hazardous energy of 240VA.