TDK-Lambda HWS300-600 Manuals

ManualLib has 5 documents for the TDK-Lambda HWS300-600: 2 user manuals, 3 installation guides. Every file can be read online or downloaded as a PDF for free.

User Manual 2Installation Guide 3

Key facts

Model
HWS300-600
Documents
5
Languages
ZH · EN
Last added
2026-11-19

Start here

TDK-Lambda HWS300 - 600 Series Instruction Manual

TDK-Lambda HWS300 - 600 Series Instruction Manual

User Manual 19 pages · 564 KB · EN

This manual provides safety warnings and installation instructions for the TDK-Lambda HWS300-600 Series power supplies. It emphasizes proper mounting, environmental conditions, and electrical safety to prevent fire, electric shock, or damage. Users must follow all cautions, especially regarding flammable environments, moisture, and unauthorized modifications.

The manual also covers terminal connections, output voltage adjustment, and long-term storage guidelines. It includes warnings about high voltage, proper grounding, and the need for professional service if repairs are required. Storage should be in controlled environments (5°C–30°C, 40%–60%RH) for up to 2 years.

Read online

TDK-Lambda HWS300-600 specifications

Input Voltage Range85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 330VDC
Output Voltage Range±20% of rated output voltage (48V Output Model: -20% ~ +10%)
Over Voltage Protection (OVP) Trigger125-145% of rated output voltage (48V type: 115-135%)
Over Current Protection (OCP) Trigger105% (24V output model: 119%) of maximum DC output current
Low Output Detection Circuit (PF) Threshold65 ~ 80% of rated value

Source: TDK-Lambda HWS300-600 Series Power Module User Manual

All TDK-Lambda HWS300-600 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Installation Guide 3

Mounting, wiring and first power-up. Read it before the hardware goes in.

Questions answered in these manuals

What is the input voltage range for this power module?

The input voltage range is 85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 330VDC.

From: TDK-Lambda HWS300-600 Series Power Module User Manual

How do I adjust the output voltage?

Use the V.ADJ trimmer on the front panel; turning it clockwise increases the output voltage.

From: TDK-Lambda HWS300-600 Series Power Module User Manual

Can this product be used as a standalone device?

No, it is designed to be installed within host equipment and must not be operated as a stand-alone product.

From: TDK-Lambda HWS300-600/M Installation Manual

Who can service this product?

Only TDK-Lambda UK LTD and their authorized agents are permitted to carry out repairs.

From: TDK-Lambda HWS300-600/M Installation Manual

Can this power supply be used as a standalone device?

No, it is a component power supply and must be installed within other equipment by qualified personnel.

From: TDK-Lambda HWS300-600 Series Switch Power Supplies Installation Manual

Who can service or repair this unit?

Only TDK-Lambda UK LTD and their authorized agents are permitted to carry out repairs.

From: TDK-Lambda HWS300-600 Series Switch Power Supplies Installation Manual