TDK-Lambda PFH500F Series 500W AC-DC Power Modules Data Sheet

TDK-Lambda PFH500F Series 500W AC-DC power module datasheet with model selection, specifications, pinout, connection diagram and derating curves.


TDK-Lambda PFH500F Series 500W AC-DC Power Modules Data Sheet - cover page
Brand
TDK-Lambda
Category
AC-DC Power
Document type
Datasheet
Language
English
Pages
5
File format
PDF
File size
1.2 MB
Published
24 November, 2026
Updated
24 November, 2026
Model
PFH500F
MD5 checksum
073A9CA59878368FA445F2ED262D1142

About this manual

The TDK-Lambda PFH500F Series data sheet describes 500 W PCB-mounted AC-DC power modules in a 4.00 x 2.40 x 0.53 in metal-case brick package. The modules accept 85–265 Vac, with possible low-line derating, and offer nominal 12, 28 or 48 V outputs for conduction-cooled applications.

It includes model selection, electrical and environmental specifications, PMBus monitoring and programming functions, pin assignments, a basic connection diagram, mechanical specifications and derating curves. Related products and evaluation kits are also listed, and optional droop-mode current sharing supports paralleling for higher power or redundant applications.

What's inside

  • Model Selector
  • Specifications
  • Related Products
  • PMBus Monitoring and Programming Functions
  • Pinout
  • PFH500F Basic Connection Diagram
  • Mechanical Specification
  • PFH500F-12 Derating Curve
  • PFH500F-28 Derating Curve
  • PFH500F-48 Derating Curve

Specifications

Nominal output power500 W
Maximum output power504 W
Input voltage range85–265 Vac; low-line derating may apply
Input frequency47–63 Hz
Nominal output voltages12, 28 and 48 Vdc
Typical efficiency90/92% at 115/230 Vac and 100% load for PFH500F-12 and PFH500F-28
Package size101.6 x 61.0 x 13.3 mm (4.00 x 2.40 x 0.53 in)
Weight225 g
Operating baseplate temperature-40 to 100 °C; see derating curves
CoolingConduction
Communications interfaceI²C / PMBus
Auxiliary output10–14 Vdc at up to 200 mA
Safety certifications and markingsIEC/UL/CSA/EN62368-1, 60950-1, CE and UKCA

Frequently asked questions

What input voltage range do the PFH500F modules accept?

They accept 85–265 Vac; low-line derating may apply.

Which nominal output voltages are available?

The series offers nominal 12, 28 and 48 V outputs.

Can the PFH500F modules be monitored and programmed remotely?

Yes. The PMBus interface supports read/write remote monitoring and programming.

Can the modules be operated in parallel?

Yes. Parallel operation uses droop-mode current-share models and the main output voltage only.

Download PDF (1.2 MB)