Key facts
- Brand
- TDK-Lambda
- Model
- CPFE1000F
- Category
- Power System Manager
- Documents
- 3
- Languages
- EN
- Last added
- 2026-11-21
Start here

TDK-Lambda CPFE1000F Series 1000W Single Output Power Supply Product Leaflet
TDK-Lambda CPFE1000F Series is a 1000W single-output, conduction/baseplate-cooled power supply with a wide-range AC input. It is fanless and provides I²C interface monitoring, remote on/off, current sharing and a 2-year warranty.
Available output models include 12V, 28V and 48V with adjustment ranges and maximum currents listed in the quick selector. The leaflet also specifies input, output, immunity, emissions, environmental and safety approval details.
TDK-Lambda CPFE1000F specifications
| Input voltage | 90-265 Vac |
|---|---|
| Input frequency | 47-63 Hz (440 Hz with reduced PFC) |
| Input harmonics | EN61000-3-2 compliant |
| Power factor | 0.95 typical |
| Inrush current | <40 A at 25°C and 230 Vac (cold start) |
| Earth leakage current | 1.5 mA at 23 Vac (50 Hz) |
| Total output power | 1008 W continuous (12V versions = 720 W) |
| Turn-on time | 1.5 s max at 90 Vac and 100% rated output power |
| Efficiency | 79-86% typical (model dependent) |
| Hold-up time | 25 ms typical at 230 Vac, 100% load |
| Ripple and noise | <1% pk-pk (2% below 0°C) |
| Voltage setting accuracy | ±2% at 50% load |
| Remote sense | Yes, max 0.5 V total line drop |
| Minimum load | No |
| Total regulation | <4% |
| Transient response | <10% of set voltage for 50% load change |
| Recovery time | 500 µs to 2% of set voltage |
| Overvoltage protection | Yes, auto recovery |
| Short-circuit protection | Yes, auto recovery after removal |
| Overtemperature protection | Yes, auto recovery |
| Baseplate temperature | -40°C to 85°C operational (-40°C to 70°C for CPFE1000F-28/-48 below 170 Vac); -40°C to 100°C storage |
| Low-temperature startup | -40°C |
| Humidity | 20-95% RH non-condensing (non-operating 10-95% RH) |
| Shock | Conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI |
| Vibration | Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1,9 |
| Altitude | -200 to 2000 m operational (-200 to 5000 m storage/transportation) |
| Pollution degree | 2, material group IIIb |
| Isolation | Input to output 4.24 kVdc; input to earth 2.12 kVdc; output to earth 500 Vdc |
| Standby supply | 12 V ±2 V / 20 mA |
| Current share | Maximum 6 units of the same model |
| Safety approvals | IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1, CE Mark |
Source: TDK-Lambda CPFE1000F Series 1000W Single Output Power Supply Product Leaflet
All TDK-Lambda CPFE1000F documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
Which output voltage models are available for the CPFE1000F Series?
The quick selector lists 12 V, 28 V and 48 V models: CPFE1000F-12, CPFE1000F-28 and CPFE1000F-48.
From: TDK-Lambda CPFE1000F Series 1000W Single Output Power Supply Product Leaflet
Is the CPFE1000F Series fanless?
Yes, it is fanless and baseplate cooled.
From: TDK-Lambda CPFE1000F Series 1000W Single Output Power Supply Product Leaflet
Who is permitted to carry out repairs on this power supply?
Only TDK-Lambda UK LTD and their authorised agents are permitted to carry out repairs.
Can this power supply be used as a standalone product?
No, this product must not be operated as a stand alone product and is only to be installed within other equipment.
Can this product be used as a standalone device?
No, it is designed to be installed within other equipment and must not be operated as a standalone product.
From: TDK-Lambda CPFE1000FI Component Power Module Installation Manual
Who can service this product?
Only TDK-Lambda UK LTD and their authorised agents are permitted to carry out repairs.
From: TDK-Lambda CPFE1000FI Component Power Module Installation Manual