This instruction manual covers the TDK-Lambda PFH05W evaluation test board (PFH05W##-100-EVK-S1 and PFH05W##-1D0-EVK-S1) used to evaluate PFH500F AC-DC power modules. It opens with safety warnings and cautions, lists the reference documents, and gives ordering information for the kits, which accept 85-265 Vac 50/60 Hz input and are offered with 12 V, 28 V or 48 Vdc output modules in non-droop or droop mode versions.

The getting-started chapters describe the required test equipment, the input and output connections, and the primary and secondary test points, followed by the PMBus connection (J301), the remote on/off switch SW200, the auxiliary voltage and power-good LEDs, and how to set the PMBus address. The remaining chapters provide the electrical schematic drawing, bill of material and board files, including bottom layer and component placement figures.

What's inside

  • Ordering Information
  • Evaluation Kit Description
  • Getting Started
  • Test Equipment
  • Test Setup
  • Test Points
  • PMBus and Remote On/Off Functions
  • Setting the PMBus Address
  • Electrical Schematic Drawing
  • Bill of Material

Specifications

Rated input85-265 Vac, 50/60 Hz
Rated output voltage options12 Vdc, 28 Vdc or 48 Vdc (depending on kit)
Rated output current42.0 A at 12 V, 18.0 A at 28 V, 10.5 A at 48 V
Recommended input fuse10 A, 250 V fast acting
Required AC sourceSingle-phase, 85 V AC - 265 V AC, 47 Hz - 63 Hz, adjustable
Default PMBus address0x19 (Hex)
Auxiliary voltage LED thresholdTurns on when the 450 Vdc bulk capacitors are energized above 70 Vdc
PMBus interface adapterTexas Instruments Interface Adapter EVM, P/N USB-TO-GPIO

Frequently asked questions

What test equipment is needed for the evaluation board?

An adjustable single-phase AC source of 85-265 Vac, 47-63 Hz, a DC multimeter with a 0-500 V range, a DC output load rated 60 Vdc or greater and 500 W or greater, and a fan for airflow across the module heatsink.

What is the factory default PMBus address?

The default address is 0x19 (Hex), with R318 not populated and R319 populated with 1.00K.

Which fuse rating is recommended for the module?

A 10 A, 250 V fast acting fuse should be used with each module.

How do I communicate with the PFH module over PMBus?

Connect through PMBus connector J301 using the Texas Instruments Interface Adapter EVM, part number USB-TO-GPIO.