Key facts
- Brand
- STMicroelectronics
- Model
- ACS108
- Documents
- 3
- Languages
- EN
- Last added
- 2012-08-10
Start here
ST ACS108-6S Overvoltage protected AC switch (ACS ) handbook
The ACS108-6S is an overvoltage protected AC switch that eliminates the need for external protection snubbers or varistors. It enables equipment to meet IEC 61000-4-5 standard and reduces component count by up to 80%. It interfaces directly with the micro-controller and supports connection of several ACS switches on the same cooling pad.
Read onlineAll STMicroelectronics ACS108 documents by type
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What standard defines the test procedure for ring wave surges?
The test procedure is described in the UL858A standard.
From: STMicroelectronics AN1296 Application Note Ring Wave Tests with ACS108
What happens if a valve has insufficient insulation during a ring wave test?
If the valve insulation breaks down, the load behaves like a short-circuit and current could reach up to 120 A.
From: STMicroelectronics AN1296 Application Note Ring Wave Tests with ACS108