Key facts
- Brand
- STMicroelectronics
- Model
- ACS108
- Documents
- 3
- Languages
- EN
- Last added
- 2012-08-10
Start here

STMicroelectronics ACS108-6S Overvoltage Protected AC Switch Datasheet
The ACS108-6S is an alternating current line switch designed for use in appliances and industrial control systems. It features integrated overvoltage protection via crowbar technology, eliminating the need for external snubbers or varistors. The device can control loads up to 0.8 A and interfaces directly with microcontrollers.
Read onlineSTMicroelectronics ACS108 specifications
| On-state rms current | 0.8 A |
|---|---|
| Non repetitive surge peak on-state current | 7.6 A |
| Peak gate current | 1 A |
| Peak positive gate voltage | 10 V |
| Non repetitive line peak mains voltage | 2 kV |
| Static dV/dt immunity | > 500 V/us |
Source: STMicroelectronics ACS108-6S Overvoltage Protected AC Switch Datasheet
All STMicroelectronics ACS108 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
Does the ACS108-6S require external protection components?
No, it needs no external protection snubber or varistor.
From: STMicroelectronics ACS108-6S Overvoltage Protected AC Switch Datasheet
What is the maximum load current?
The switch can control a load of up to 0.8 A.
From: STMicroelectronics ACS108-6S Overvoltage Protected AC Switch Datasheet
Does the ACS108 require external protection components?
No, the ACS108 needs no external protection snubber or varistor.
From: STMicroelectronics ACS108 Overvoltage Protected AC Switch Datasheet
What is the maximum load current for the ACS108?
The ACS108 can control a load of up to 0.8 A.
From: STMicroelectronics ACS108 Overvoltage Protected AC Switch Datasheet
What standard defines the test procedure for ring wave surges?
The test procedure is described in the UL858A standard.
From: STMicroelectronics AN1296 Application Note Ring Wave Tests with ACS108
What happens if a valve has insufficient insulation during a ring wave test?
If the valve insulation breaks down, the load behaves like a short-circuit and current could reach up to 120 A.
From: STMicroelectronics AN1296 Application Note Ring Wave Tests with ACS108