Siemens SITRANS Probe LU240 ultrasonic level transmitter for continuous level, volume, and volume flow measurement up to 12 m.
SITRANS Probe LU240 is an ultrasonic level transmitter for continuous level, volume, and volume flow measurement in liquids, slurries, and bulk materials up to 12 m (40 ft). It is intended for applications such as water and wastewater, chemical storage vessels, and small bulk hoppers.
The transmitter offers easy installation and simple startup, programming with a 4-button HMI or SIMATIC PDM, HART communication on certain models, mA output on all models, ETFE or PVDF transducers, Process Intelligence signal processing, and Auto False Echo Suppression. Optional Bluetooth configuration and monitoring is available via SITRANS mobile IQ.
| Measuring principle | Ultrasonic level measurement |
|---|---|
| Measuring range | 0.2 to 12 m (8 inch to 40 ft), depending on model |
| Frequency | 54 kHz |
| Output | 4 to 20 mA; HART on certain models |
| Accuracy | 3 m version: 10 mm; 6 m and 12 m versions: greater of 0.15% of range or 6 mm, valid from 0.25 m; ±2 mm on ranges 4 m or less |
| Resolution | ≤3 mm (0.12 inch) |
| Non-repeatability | ≤3 mm (0.12 inch) |
| Blanking distance | 0.2 m (0.66 ft) |
| Update time | ≤4 s |
| Beam angle | 10° |
| Ambient operating temperature | -40 to +80 °C (-40 to +176 °F) |
| Ambient storage temperature | -40 to +85 °C (-40 to +185 °F) |
| Medium temperature at flange or threads | -40 to +85 °C (-40 to +185 °F) |
| Vessel pressure | 0.5 bar g (7.25 psi g) |
| Enclosure material | PBT (Polybutylene Terephthalate) |
| Degree of protection | Type 4X, Type 6, IP66, IP68 |
| Weight | 0.93 kg (2.1 lb) |
| Transducer material | ETFE or PVDF |
| Process connection | 2 inch NPT, R 2 inch, or G 2 inch threaded; 3 inch (80 mm) universal flange |
| Power supply | 10.5 to 30 V DC (4 to 20 mA/HART) |
The measuring range is 0.2 to 12 m (8 inch to 40 ft), depending on the model.
The transducer is available in ETFE or PVDF.
HART communication is available on certain models, and all models provide mA output.
± the greater of 0.15% of range or 6 mm (0.25 inch), valid from 0.25 m (0.82 ft); ±2 mm (0.08 inch) on ranges 4 m (13 ft) or less.