Pentair IntelliChlor IC60/IC40/IC20/IC15 Installation and User's Guide
The document serves as the official installation and user guide for the Pentair IntelliChlor Electronic Chlorine Generator series, specifically models IC60, IC40, IC20, and IC15. It covers essential safety warnings regarding salt corrosion and electrical hazards, along with system component identification.
Read onlinePentair IC20 specifications
| Compatible Cells | IntelliChlor model IC20 and IC40 |
|---|---|
| Fuse Rating | 8 AMP slo-blo fuse |
| Output Voltage | 35 VDC |
| Mounting Distance Limit | No more than 15 feet from cell controller |
| Minimum Flow Rate | 20 gpm |
Source: Pentair Water IC20/IC40 IntelliChlor Power Center Installation Guide
All Pentair IC20 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
What tools are required for installation?
Required tools include Phillips & Flathead Screwdrivers, a Voltmeter to determine AC line voltage, and an Electric drill with a 1/4" masonry drill bit.
From: Pentair Water IC20/IC40 IntelliChlor Power Center Installation Guide
How far can the Power Center be mounted from the cell?
The Power Center enclosure must be mounted no more than 15 feet away from the cell controller.
From: Pentair Water IC20/IC40 IntelliChlor Power Center Installation Guide
What type of salt should be used with IntelliChlor?
The manual advises reviewing the section on 'Chemistry You Need to Know' and 'What Type of Salt to Use' for specific recommendations.
From: Pentair IntelliChlor IC20/IC40 Electronic Chlorine Generator Installation and User's Guide
Can the IntelliChlor unit be installed vertically or horizontally?
Yes, the cell assembly can be installed in either orientation.
From: Pentair IntelliChlor IC20/IC40 Electronic Chlorine Generator Installation and User's Guide
What models is this power center compatible with?
It is for use with IntelliChlor model IC60, IC40 and IC20.
From: Pentair IntelliChlor Power Center Installation Guide for IC60/IC40/IC20
Where should the power center be mounted?
It can be mounted vertically on a flat surface such as a wall or post no more than 15 feet away from the cell controller.
From: Pentair IntelliChlor Power Center Installation Guide for IC60/IC40/IC20