Key facts
- Brand
- Pentair
- Model
- IC20
- Industry
- Industrial
- Documents
- 7
- Languages
- ES · EN · IT
- Last added
- 2023-11-10
Start here

Pentair IntelliChlor IC60/IC40/IC20/IC15 Installation and User's Guide
The document serves as the official installation and user guide for the Pentair IntelliChlor Electronic Chlorine Generator series, specifically models IC60, IC40, IC20, and IC15. It covers essential safety warnings regarding salt corrosion and electrical hazards, along with system component identification.
Read onlinePentair IC20 specifications
| Model | IC20 and IC40 |
|---|---|
| Application | Pool and spa chlorination |
| Certifications | CE pending; NSF and ANSI 50 |
| Electrical supply | 110 VAC and 220 VAC |
| Minimum distance from pool wall | At least 5 feet |
| Minimum distance from heater outlet | Two (2) feet |
| Grounding conductor | Not smaller than No. 8 AWG (8.4 mm) |
All Pentair IC20 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Pentair IntelliChlor IC20/IC40 Pool and Spa Electronic Chlorine Generator Installation and User Guide 32 p
- Pentair IntelliChlor IC20/IC40 Electronic Chlorine Generator Installation and User's Guide 32 p
- Pentair IntelliChlor IC20/IC40 Chlorine Generator User and Installation Manual 32 p
- Pentair IntelliChlor IC60/IC40/IC20/IC15 Installation and User's Guide 46 p
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
What models does the Pentair IntelliChlor guide cover?
The guide covers the IntelliChlor electronic chlorine generator models IC20 and IC40.
What is the IntelliChlor used for?
It is an electronic chlorine generator for swimming pools and spas.
What tools are required for installation?
Required tools include Phillips & Flathead Screwdrivers, a Voltmeter to determine AC line voltage, and an Electric drill with a 1/4" masonry drill bit.
From: Pentair Water IC20/IC40 IntelliChlor Power Center Installation Guide
How far can the Power Center be mounted from the cell?
The Power Center enclosure must be mounted no more than 15 feet away from the cell controller.
From: Pentair Water IC20/IC40 IntelliChlor Power Center Installation Guide
What type of salt should be used with IntelliChlor?
The manual advises reviewing the section on 'Chemistry You Need to Know' and 'What Type of Salt to Use' for specific recommendations.
From: Pentair IntelliChlor IC20/IC40 Electronic Chlorine Generator Installation and User's Guide
Can the IntelliChlor unit be installed vertically or horizontally?
Yes, the cell assembly can be installed in either orientation.
From: Pentair IntelliChlor IC20/IC40 Electronic Chlorine Generator Installation and User's Guide