Pentair 5800 LXT Manuals

ManualLib has 3 documents for the Pentair 5800 LXT: 3 service manuals. Every file can be read online or downloaded as a PDF for free.

Service Manual 3

Key facts

Brand
Pentair
Model
5800 LXT
Documents
3
Languages
EN · FR
Last added
2023-10-18

Start here

Pentair FLECK 5800 LXT Downflow/Upflow Service Manual

Pentair FLECK 5800 LXT Downflow/Upflow Service Manual

Service Manual 20 pages · 2.8 MB · EN

This service manual provides detailed instructions for installing, operating, and troubleshooting the Pentair FLECK 5800 LXT water softener valve. It includes sections on control features, programming modes, diagnostic viewing, and component assembly such as powerhead, control valve, and bypass valves. Safety and installation guidelines are emphasized, including electrical requirements, plumbing considerations, and environmental restrictions. The manual also includes tables for system configuration based on tank size and resin volume.

Read online

Pentair 5800 LXT specifications

Water Pressure Minimum20 psi (1.4 bar)
Electrical Supply120 VAC
Controller Voltage12 VDC
Maximum Water Pressure125 psi (8.6 bar)
Maximum Water Temperature110°F (43°C)

Source: Pentair FLECK 5800 LXT Downflow/Upflow Service Manual

All Pentair 5800 LXT documents by type

Questions answered in these manuals

What is the minimum water pressure required for the valve to operate?

A minimum of 20 psi (1.4 bar) of water pressure is required for the regeneration valve to operate effectively.

From: Pentair FLECK 5800 LXT Downflow/Upflow Service Manual

What voltage does the controller require?

The controller operates on 12-volt DC power supply.

From: Pentair FLECK 5800 LXT Downflow/Upflow Service Manual

What is the minimum water pressure required for the FLECK® 5800 LXT to operate?

A minimum of 20 psi (1.4 bar) of water pressure is required for the regeneration valve to operate effectively.

From: Pentair FLECK® 5800 LXT Downflow/Upflow Service Manual

What electrical supply is required for the FLECK® 5800 LXT?

An uninterrupted 120 VAC supply is required, which is converted to 12 VDC via a transformer.

From: Pentair FLECK® 5800 LXT Downflow/Upflow Service Manual

What is the minimum water pressure required for the Fleck 5800 LXT?

A minimum water pressure of 1.4 bar (20 psi) is required for proper valve regeneration operation.

From: Pentair Fleck 5800 LXT Co-current/Counter-current Water Softener Maintenance Manual

What is the maximum water pressure this unit can handle?

The unit is designed to handle a maximum pressure of 8.6 bar (125 psi), but a pressure regulator must be installed if pressure exceeds 5.5 bar (80 psi).

From: Pentair Fleck 5800 LXT Co-current/Counter-current Water Softener Maintenance Manual