Pentair FLECK 2850 Manuals

ManualLib has 3 documents for the Pentair FLECK 2850: 1 datasheet, 1 service manual, 1 product leaflet. Every file can be read online or downloaded as a PDF for free.

Datasheet 1Service Manual 1Product Leaflet 1

Key facts

Brand
Pentair
Model
FLECK 2850
Documents
3
Languages
EN
Last added
2026-10-06

Start here

Pentair FLECK 2850 Commercial Control Valve Valve Specifications

Pentair FLECK 2850 Commercial Control Valve Valve Specifications

Datasheet 2 pages · 408 KB · EN

The FLECK 2850 Commercial Control Valve is designed for small commercial and industrial water‑treatment applications. It features a lead‑free brass body, continuous service flow of 46 GPM, backwash capability up to 47 GPM, and fully adjustable 3‑ or 5‑cycle control for softener or filter systems. Optional accessories include electromechanical timers, LCD displays, and network modules for multi‑valve control.

Technical specifications include a 1‑1/2" NPTF/BSPF inlet/outlet, Cv of 12 at 1 psi drop, electrical rating 24/110/220 V 50/60 Hz, and temperature ranges from 34 °F to 180 °F. The valve is UL recognized, NSF/ANSI certified, and suitable for single or multiple‑tank installations.

Read online

Pentair FLECK 2850 specifications

Valve materialLead‑free brass
Inlet/Outlet size1‑1/2" NPTF/BSPF
Continuous flow rate46 GPM (15 psi drop)
Maximum backwash flow47 GPM (25 psi drop)
Adjustable cycles3 or 5
Cv (flow coefficient)12 at 1 psi drop
Electrical rating24/110/220 V, 50/60 Hz
Cold water temperature range34 °F – 110 °F
Hot water temperature range34 °F – 180 °F
Distributor pilot diameter1.9" O.D. (50 mm)

Source: Pentair FLECK 2850 Commercial Control Valve Valve Specifications

All Pentair FLECK 2850 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

What is the maximum continuous flow rate of the FLECK 2850 valve?

The valve provides a continuous flow rate of 46 GPM at a 15 psi pressure drop.

From: Pentair FLECK 2850 Commercial Control Valve Valve Specifications

How many cycles can be set on the valve?

The valve can be configured for either 3 or 5 cycles.

From: Pentair FLECK 2850 Commercial Control Valve Valve Specifications

What is the minimum water pressure required for the FLECK 2850 to operate?

Minimum operating pressure: 20 psi / 1.4 bar / 138 kPa.

From: Pentair FLECK 2850 Control Valve Service Manual

What is the maximum operating pressure for the FLECK 2850?

Maximum operating pressure: 125 psi / 8.61 bar / 861 kPa.

From: Pentair FLECK 2850 Control Valve Service Manual

What materials is the Fleck 2850 valve made from?

The valve body is made of lead-free brass, as defined by the U.S. EPA Safe Drinking Water Act.

From: Pentair Fleck 2850 Commercial Control Valves Product Leaflet

What is the maximum backwash flow rate?

The maximum backwash flow rate is 47 GPM (10.7 m3/h).

From: Pentair Fleck 2850 Commercial Control Valves Product Leaflet