Pentair FLECK 2850 Control Valve Service Manual
This document serves as a service manual for the Pentair FLECK 2850 Control Valve, providing detailed instructions for installation, start-up, and timer setting procedures. It covers various timer models including the 3200, 3210, 3220, and 3230, along with specific assembly instructions for different powerhead and brine system configurations.
The manual includes comprehensive job specification sheets, installation guidelines regarding water pressure and electrical facilities, and step-by-step start-up instructions. It also details troubleshooting procedures, flow diagrams, and wiring information for multiple system types.
Pentair 2850 specifications
| Minimum Water Pressure | 20 pounds (1.4 bar) |
|---|---|
| Maximum Water Pressure | 125 psi (8.6 bar) |
| Maximum Water Temperature | 110°F (43°C) |
| Residential Drain Line Size | 1/2-inch (13 mm) |
| Commercial Drain Line Size | Same as drain line flow control |
All Pentair 2850 documents by type
Disassembly, diagnostics and part numbers, for repair.
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the minimum water pressure required for the valve to operate?
A minimum of 20 pounds (1.4 bar) of water pressure is required for regeneration valve to operate effectively.
What type of sealant should be used on the drain fitting?
Plumber tape is the only sealant to be used on the drain fitting.
What is the maximum continuous flow rate of the FLECK 2850 valve?
The valve provides a continuous flow rate of 46 GPM at a 15 psi pressure drop.
From: Pentair FLECK 2850 Commercial Control Valve Valve Specifications
How many cycles can be set on the valve?
The valve can be configured for either 3 or 5 cycles.
From: Pentair FLECK 2850 Commercial Control Valve Valve Specifications
What is the minimum water pressure required for the FLECK 2850 to operate?
Minimum operating pressure: 20 psi / 1.4 bar / 138 kPa.
What is the maximum operating pressure for the FLECK 2850?
Maximum operating pressure: 125 psi / 8.61 bar / 861 kPa.