Pentair 2850 Manuals

ManualLib has 4 documents for the Pentair 2850 (Other): 2 service manuals, 1 datasheet, 1 product leaflet. Every file can be read online or downloaded as a PDF for free.

Service Manual 2Datasheet 1Product Leaflet 1

Key facts

Brand
Pentair
Model
2850
Category
Other
Industry
Appliances
Documents
4
Languages
EN
Last added
2026-11-02

Start here

Pentair FLECK 2850 Control Valve Service Manual

Pentair FLECK 2850 Control Valve Service Manual

Service Manual 52 pages · 3.8 MB · EN

This document serves as a service manual for the Pentair FLECK 2850 Control Valve, providing detailed instructions for installation, start-up, and timer setting procedures. It covers various timer models including the 3200, 3210, 3220, and 3230, along with specific assembly instructions for different powerhead and brine system configurations.

The manual includes comprehensive job specification sheets, installation guidelines regarding water pressure and electrical facilities, and step-by-step start-up instructions. It also details troubleshooting procedures, flow diagrams, and wiring information for multiple system types.

Read online

Pentair 2850 specifications

Minimum Water Pressure20 pounds (1.4 bar)
Maximum Water Pressure125 psi (8.6 bar)
Maximum Water Temperature110°F (43°C)
Residential Drain Line Size1/2-inch (13 mm)
Commercial Drain Line SizeSame as drain line flow control

Source: Pentair FLECK 2850 Control Valve Service Manual

All Pentair 2850 documents by type

Service Manual 2

Disassembly, diagnostics and part numbers, for repair.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the minimum water pressure required for the valve to operate?

A minimum of 20 pounds (1.4 bar) of water pressure is required for regeneration valve to operate effectively.

From: Pentair FLECK 2850 Control Valve Service Manual

What type of sealant should be used on the drain fitting?

Plumber tape is the only sealant to be used on the drain fitting.

From: Pentair FLECK 2850 Control Valve Service Manual

What is the maximum continuous flow rate of the FLECK 2850 valve?

The valve provides a continuous flow rate of 46 GPM at a 15 psi pressure drop.

From: Pentair FLECK 2850 Commercial Control Valve Valve Specifications

How many cycles can be set on the valve?

The valve can be configured for either 3 or 5 cycles.

From: Pentair FLECK 2850 Commercial Control Valve Valve Specifications

What is the minimum water pressure required for the FLECK 2850 to operate?

Minimum operating pressure: 20 psi / 1.4 bar / 138 kPa.

From: Pentair FLECK 2850 Control Valve Service Manual

What is the maximum operating pressure for the FLECK 2850?

Maximum operating pressure: 125 psi / 8.61 bar / 861 kPa.

From: Pentair FLECK 2850 Control Valve Service Manual