Introduces the features and usage methods of Fluke 62 MAX and 62 MAX + Infrared Thermometers.
This document provides calibration information, safety warnings, and maintenance instructions for the Fluke 62 MAX and 62 MAX+ Infrared Thermometers. It details how to change batteries, clean the device, and contact Fluke for support or repair services.
The manual also outlines specifications for both models, including temperature ranges, accuracy, response time, and optical resolution. Furthermore, it describes the required equipment and step-by-step procedures for performing performance verification tests to ensure the thermometer operates within its specified limits.
| Temperature Range (62 MAX) | -30 °C to 500 °C (-22 °F to 932 °F) |
|---|---|
| Accuracy (≥0 °C) 62 MAX | ±1.5 °C or ±1.5 % of reading, whichever is greater |
| Accuracy (≥0 °C) 62 MAX + | ±1 °C or ±1 % of reading, whichever is greater |
| Response Time (95%) 62 MAX | <500 ms |
| Spectral Response | 8 to 14 microns |
| Emissivity Range | 0.10 to 1.00 |
| Optical Resolution (62 MAX) | 10:1 |
| Battery Life (Laser and Backlight On) 62 MAX | 10 hours |
| Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) |
| IP Rating | IEC 60529: IP 54 |
The temperature range is -30 °C to 500 °C (-22 °F to 932 °F).
The 62 MAX lasts for 10 hours, while the 62 MAX + lasts for 8 hours.
The optical resolution is 10:1, calculated at 90 % energy.