Flowline LV10 Series Vertical Buoyancy Liquid Level Switch Manual

This document introduces the features and uses of Switch-Tek™ Vertical Buoyancy Liquid Level Switch LV10 Series


Flowline LV10 Series Vertical Buoyancy Liquid Level Switch Manual - cover page
Brand
FlowLine
Category
Other Electronics
Document type
User Manual
Language
English
Pages
10
File format
PDF
File size
730 KB
Published
12 October, 2023
Updated
12 October, 2023
MD5 checksum
4819DB0763F3B453B4A7C9B45B51CD07

About this manual

The Flowline LV10 Series Vertical Buoyancy Liquid Level Switch consists of a float, magnet reed switch, and baffle body designed to eliminate switch chatter. The device operates by detecting when the probe becomes immersed in liquid, causing the float to become buoyant and elevate the magnet to change the reed switch state. It is available in two wetted material versions: Polypropylene (PP) and Polyvinylidene Fluoride (PVDF).

The manual covers specifications such as accuracy, repeatability, and temperature ranges, along with detailed installation procedures for top wall mounting and connection to Switch Car Kits. It also provides specific wiring instructions for Flowline controllers and outlines a maintenance procedure for cleaning the sensor to prevent jamming.

What's inside

  • Specifications
  • Dimensions
  • Safety Precautions
  • Installation
  • Top Wall Installation
  • Bayonet Connection
  • Electrical
  • Wiring
  • Maintenance
  • Warranty

Specifications

Accuracy±2mm in water
Repeatability±1mm in water
Orientation±20˚ from vertical
Specific Gravity0.8 minimum
Contact Rating15VA, 0.25A max.
Contact Voltage120 VAC, 120 VDC @ 15 VA
Temperature Range-40˚ to 80˚ C
Pressure Range25 psi (2 bar) @ 25˚ C.
Sensor MaterialPolypropylene (PP) or PVDF
Cable Length10' (3m)

Frequently asked questions

What is the maximum supply voltage for the LV10 switch?

The supply voltage should never exceed 120 volts AC @ 15 VA for the LV10-_3_1 model.

Can the LV10 series be used in hazardous applications?

It should not be used within flammable or explosive applications unless properly connected to an approved control device.

What materials are the LV10 switches made of?

The switch and cable jacket are made of Polypropylene (PP) for LV10-13_1, and PVDF with FEP jacket for LV10-53_1.

How should the LV10 switch be cleaned?

Use a soft bristle brush and mild detergent, avoiding harsh abrasives or incompatible solvents.

Download PDF (730 KB)